<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T02:17:44Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/11345" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/11345</identifier><datestamp>2026-09-24T06:27:27Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Fang, Qiyin</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Hayward, Joseph E.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Haugen, Harold K.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Emigh, Brent J.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Medical Physics</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2014-06-18T16:54:21Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2014-06-18T16:54:21Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="created" lang="en_US">2011-09-28</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2011-10</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="other" lang="en_US">opendissertations/6319</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="other" lang="en_US">7371</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="other" lang="en_US">2262372</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/11345</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/21576</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">&lt;p>Mechanical oscillating drills and saws are used in orthopaedic surgery to cut bone and develop screw-holes; however, their use causes friction resulting in significant thermal damage. Ultrashort pulsed lasers appear well-suited to replace traditional tools as they have the ability to efficiently remove bone tissue while causing only minimal collateral damage. Laser ablation also has the added advantages of: (i) no mechanical vibration; (ii) minimal invasiveness; and (iii) small focus spot size. In this thesis work, we experimentally investigated a few key aspects of ultrashort laser ablation of bone tissue.&lt;/p> &lt;p>The ablation threshold of unaltered bone was measured using the &lt;em>D&lt;/em>&lt;sup>2 &lt;/sup>technique and found to range from 1.66 J/cm&lt;sup>2 &lt;/sup>± 0.87 J/cm&lt;sup>2&lt;/sup> to 2.37 J/cm&lt;sup>2 &lt;/sup>± 0.78 J/cm&lt;sup>2&lt;/sup> depending on incident pulse number. The reduction in ablation threshold with pulse number was an indication of an incubation effect. Using a power law model, the incubation coefficient, ζ, was measured to be 0.89 ± 0.03.&lt;/p> &lt;p>The effect of specific laser parameters and drilling protocols on ablation efficiency was also characterized. For ultrashort pulses (≤10 ps), the removal rate was found to be inversely related to the pulse duration; however, irradiation with 5-10 ps pulses were also shown to result in significant tissue removal. With a pulse repetition rate of 1 kHz, the removal rate was observed to be highest when ablating with 50-100 pulses per spot.&lt;/p> &lt;p>Larger volumes (>1 mm&lt;sup>3&lt;/sup>) of bone tissue were removed using laser scanning procedures. A series of scanned concentric circles produced a structure ~2.4 mm deep; however, ablated side-lobes were present at oblique angles to the incident beam. A two-layer structure subsequently produced no side-lobes. The ablative precision in trabecular bone was observed to be less than cortical bone. Using mimicked Nd:YAG laser parameters, cylindrical drilling produced craters significantly less deep than those achieved with a typical Ti:Sapphire configuration. The ability to drill large-scale holes using low average pulse energies and optimized scanning procedures will alleviate the stringent requirements for optical components in clinical practice.&lt;/p></dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Science (MSc)</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Laser ablation</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">femtosecond</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">bone</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">ultrafast material processing</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">incubation</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Bioimaging and biomedical optics</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Bioimaging and biomedical optics</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Experimental Evaluation of Bone Drilling using Ultrashort Pulsed Laser Ablation</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">thesis</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>