<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T07:58:17Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/12750" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/12750</identifier><datestamp>2026-09-24T07:50:28Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Ostapiak, Orest</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Nichita, Eleodor</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Medical Physics</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2014-06-18T17:00:40Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2014-06-18T17:00:40Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="created" lang="en_US">2012-11-21</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2013-04</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="other" lang="en_US">opendissertations/7609</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="other" lang="en_US">8664</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="other" lang="en_US">3485063</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/12750</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/14215</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">&lt;p>Intensity-Modulated Radiation Treatment (IMRT) requires patient-specific quality assurance measurements, which can benefit from the convenience of using an Electronic Portal Imaging Device (EPID) for dose verification. However, EPIDs have limitations stemming from the non-uniform backscatter due to the support-arm as well as from scatter, glare, and an increased sensitivity to low-energy photons. None of these effects is typically accounted for in a treatment planning system (TPS) model, resulting in errors in calculated EPID response of up to 6%. This work addresses the non-uniform backscatter by directly incorporating a support-arm backscatter region into the TPS geometry. The shape of the backscatter region is adjusted iteratively until the TPS-calculated flood-field planar dose matches the flood-field EPID image The scatter, glare and increased low-energy response are addressed by using a radially-dependent Point-Spread Function (Kernel). The kernel is fitted using a least-squares method so that it best reproduces the EPID-acquired image for a checkerboard field. The backscatter-correction method is implemented for a Varian Clinac equipped with a 40 cm x 30 cm (512 x 384 pixel) EPID and a Pinnacle&lt;sup>3&lt;/sup> TPS and tested for several rectangular and IMRT fields. The scatter, glare and energy-response correction kernel is implemented and tested for a simulated checkerboard field and a simulated IMRT field. Agreement between the EPID-measured image and TPS-calculated planar dose map is seen to improve from 6% to 2% when the backscatter region is added to the Pinnacle&lt;sup>3&lt;/sup> model. Agreement between the simulated EPID images and simulated TPS images is improved from 14% to approx. 1% when the radially-dependent kernel is used. Simultaneous application of both the backscatter region and Point-Spread Function is a promising direction for future investigations.&lt;/p></dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Science (MSc)</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">IMRT dose verification</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">portal dosimetry</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">EPID dosimetry</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">amorphous silicon</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Other Physics</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Other Physics</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">A Study of IMRT Pre-Treatment Dose Verification Using a-Si Electronic Portal Imaging Devices</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">thesis</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>