<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T07:32:13Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/15394" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/15394</identifier><datestamp>2026-09-24T05:31:47Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Ziada, Samir</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Lightstone, Marilyn</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Rancic, Slobodan</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2014-06-26T18:52:51Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2014-06-26T18:52:51Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2014</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/15394</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/14027</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">The balanced oil pump is an important component of the automatic transmission in modern&#xd;
automotive vehicles. During the pump operation, pressure pulsations are generated, which negatively&#xd;
affect the working characteristics of a pump, including pump noise and durability. Thus, pressure&#xd;
pulsations must be minimized in order to ensure smooth operation of the pump, low noise and&#xd;
increased durability.&#xd;
The current work uses Computational Fluid Dynamics (CFD) to explore the effects of port design on&#xd;
pump pressure pulsations for binary transmission vane pump. Several different approaches are&#xd;
considered, such as port length at intake and discharge, implementation of metering grooves at&#xd;
discharge and intake ports, along with different shapes of metering grooves.&#xd;
More than 20 CFD cases are analyzed to study the effect of different port design on pressure pulsations&#xd;
of the pump. Validation against experimental data is performed to provide confidence in the CFD&#xd;
modeling results. It is found that ports can be designed more precisely using CFD than described using&#xd;
the simple models that are typically used for pump analysis. Implementing metering grooves helps&#xd;
decreasing pressure pulsations. There is no significant difference in the pressure pulsation generated&#xd;
with different shapes of metering grooves in the pump non‐cavitation regime. Future work could&#xd;
consider the effects of the metering grooves geometry on feasibility and durability within the cavitation&#xd;
regime.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Applied Science (MASc)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">REDUCTION OF PRESSURE PULSATIONS ON AUTOMOTIVE TRANSMISSION OIL VANE PUMP</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>