<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T02:44:22Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/17196" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/17196</identifier><datestamp>2026-09-24T07:22:51Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Luxat, John</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Schneider, Alexander Shlomo</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Engineering Physics</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2015-04-23T17:39:40Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2015-04-23T17:39:40Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2015</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/17196</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/15780</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">A safety analysis for the McMaster Nuclear Reactor has been carried out for&#xd;
postulated scenarios of loss or termination of forced flow in the reactor core in a&#xd;
state of shutdown, with loss of pool inventory of different magnitudes including core&#xd;
uncovery. Models were developed to evaluate the natural convection flow through the&#xd;
core assemblies for the different conditions within the aforementioned envelope. The&#xd;
flow rate was used to get the temperature or enthalpy rise along the heated channel in&#xd;
order to estimate the corresponding clad temperatures in the given scenarios.&#xd;
The models were constructed from first principles using the one-dimensional momentum conservation law, incorporating the Boussinesq approximation for the single-phase&#xd;
case and the Homogeneous Equilibrium Model assumptions when a two-phase mixture&#xd;
was present. In order to obtain the flow rate and enthalpy rise along the channel,&#xd;
knowledge of the assembly power and inlet temperature is required. The power was&#xd;
calculated using a well known decay power correlation. The pool temperature which&#xd;
was used as the assembly inlet temperature was calculated via a lumped parameter&#xd;
model using a simple energy balance between the core output (again by using the&#xd;
decay-heat profile) and the pool heatup. Heat losses from the pool were neglected and&#xd;
the model allowed for reaching saturation temperature in the pool. In this case, water&#xd;
vaporization was calculated using the latent heat to assess pool inventory loss rate.&#xd;
For all scenarios before core uncovery, the models predict that clad and fuel&#xd;
temperatures remained well below limits associated with clad blistering or melting.&#xd;
Consequently, it is asserted natural convection and acceptable temperatures will be&#xd;
sustained in the McMaster Nuclear Reactor while the core remains covered. In the&#xd;
most severe draining before uncovery, in which the pool drains to just before exposing&#xd;
the core, it takes approximately a week (180 hours) after shutdown for boiling to start&#xd;
in the core’s hottest channel. For core uncovery, the models predict that the clad&#xd;
remains below the blistering temperature for pool height at 9.4% of the heated channel’s&#xd;
height (corresponding to exposing about 61.7 cm of the assembly), and below melting&#xd;
temperature for pool height at 8.1% of the heated channel’s height (corresponding to&#xd;
exposing about 62.5 cm of the assembly). Both heights are below the height of the&#xd;
bottom of the lowest beam tube, at which the worst draining case will end.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Applied Science (MASc)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Natural Convection</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Research Reactor</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Analysis of Postulated Pool Draining Accidents in the MNR</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>