<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T00:04:50Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/17547" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/17547</identifier><datestamp>2026-09-24T21:37:11Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Sinha, N. K.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Dai, Sue-Hon</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Electrical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2015-06-15T17:38:29Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2015-06-15T17:38:29Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">1970-04</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/17547</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/17892</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">&lt;p> The dual configuration is innovated as a new approach in sensitivity reduction. Three types of sensitivity due to variations in plant parameters are discussed. It has been shown that cost insensitive and terminal insensitive designs are indeed achievable by applying the dual configuration to implement the optimal control. &lt;/p> &lt;p> The theory has been developed for a general class of optimal systems and the linear systems with quadratic cost functionals have been analytically evaluated to illustrate the theory. &lt;/p></dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Engineering (ME)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">electrical engineering</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">optimal control</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">sensitivity reduction</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">plant parameter variations</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">The Implementation of Optimal Control with Sensitivity Reduction to Plant Parameter Variations.</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>