<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T02:02:52Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/17810" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/17810</identifier><datestamp>2026-09-24T04:24:29Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Thode, H. G.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Freeman, James Rowe</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Physics</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2015-07-28T17:52:16Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2015-07-28T17:52:16Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">1949-09</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/17810</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/24964</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">An investigation of several solid sources for use in isotopic analysis by means of a mass spectrometer is reported. In particular, the compound copper acetylacetonate has been successfully employed to obtain ion currents corresponding to the copper isotopes. The second portion of this thesis deals with an energy filter method of reducing scattering effects in a mass spectrometer tube.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Arts (MA)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">physics</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">90º solid, source</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">mass spectrometry</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">A 90º Solid Source Mass Spectrometer</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>