<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T04:49:19Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/17981" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/17981</identifier><datestamp>2026-09-24T19:09:09Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">McMullen, C. C.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Heyland, Gunter Rolf</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Physics</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2015-08-31T19:14:41Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2015-08-31T19:14:41Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">1967-05</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/17981</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/20387</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">&lt;p> A description of the McMaster tandem mass spectrometer is given and the usefulness of this instrument in high sensitivity applications is discussed.&lt;/p> &lt;p> The pulse characteristics of the 17 stage Allen type electron multiplier which is used on the two stage mass spectrometer were determined and possible means of achieving an improved response in counting applications are discussed.&lt;/p> &lt;p> An ion source of the crucible variety was constructed which made possible the detection of 10^-9 grams of a tin isotope. This&#xd;
source was used to detect sub microgram quantities of an enriched tin sample and was also used for the qualitative analysis of a sample which contained tin extracted from a reactor irradiated fuel rod.&lt;/p></dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Science (MSc)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en_US</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">sensitivity, tandem, mass, spectrometer, electron</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">High Sensitivity Studies Using a Tandem Mass Spectrometer</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>