<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T04:53:35Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/18514" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/18514</identifier><datestamp>2026-09-24T18:53:08Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Mahalec, Vladimir</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Baagil, Omar M.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Chemical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2015-11-03T19:25:06Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2015-11-03T19:25:06Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2015</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/18514</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/17346</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">This work suggests a new multiple ejector refrigeration cycle operated by an NGL Recovery Plant's waste heat as a replacement to the mechanical compression refrigeration cycle. This will result in significant power reduction and CO2 emission reduction.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Typical NGL plant compresses its feed to a high pressure (3040 kPa). The feed gas compressors’ discharge reaches approximately 150 OC.  After that, the feed is cooled by three-stage propane vapour compression refrigeration cycle.  This paper examines various options for thermal power cooling in such plants in order to eliminate part of the propane chilling system.  Since most of the new plants are located in desert climates, typical designs based on absorption refrigeration are not very efficient.   Design proposed in this work employs ejector refrigeration and it is based on 45 OC air as a cooling media (summer conditions in hot climates).  Performance factor has been defined as the total cooling provided by the refrigeration system over the total cooling required in the 1st cooling stage of the NGL Recovery Plant. Cooling based on a single N-pentane ejector cycle with N-pentane has COP of 0.342 and performance factor (ƞ) of 0.842. Multistage ejector N-pentane refrigeration system has COP of 0.714 and performance factor (ƞ) of 1.053.  For a typical 750 Million scf/d NGL plant, the new design saves $12 Millions in capital costs and $1.5 in annual electricity cost.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Applied Science (MASc)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Energy and Heat integration</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Refrigeration</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Renewable Energy</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">NGL Recovery Plant</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Process Design</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Ejector Refrigeration Cycle</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Absorption Refrigeration Cycle</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Solar Energy</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">CO2 Emission</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Greenhouse Emission</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">NGL RECOVERY PLANT FEED GAS COOLING BY EJECTOR REFRIGERATION – DESIGNED FOR HOT CLIMATE</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>