<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T08:10:26Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/19687" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/19687</identifier><datestamp>2026-09-24T19:57:50Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Thode, H.G.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Mills, Robert H.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Chemistry</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2016-06-29T16:21:03Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2016-06-29T16:21:03Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">1950-05</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/19687</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/10796</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Title: The Design of a Heated Mass Spectrometer Ion Source for Isotope Abundance Measurements, Author: Robert H. Mills, Location: Thode</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">A simple furnace type mass spectrometer positive ion source has been designed constructed and tested. This source operated satisfactorily under certain conditions and was used in the determination of the relative abundances of the copper isotopes.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Science (MS)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">The Design of a Heated Mass Spectrometer Ion Source for Isotope Abundance Measurements</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>