<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T04:49:17Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/20349" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/20349</identifier><datestamp>2026-09-24T22:42:23Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Baird, M. H. I.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Tessaro, Michael</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Chemical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2016-09-12T14:53:48Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2016-09-12T14:53:48Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">1973</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/20349</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/10888</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">A 5. 0 em. diameter column was used for&#xd;
gas absorption. The column contained&#xd;
internal baffling and was operated in a countercurrent mode.&#xd;
Oxygen comprised the gaseous phase and tap water the liquid&#xd;
phase. The column was operated both with and without&#xd;
pulsations. The injection and exhaustion of compressed air&#xd;
to the system provided the pulsation mechanism. The mixing&#xd;
as well as the mass transfer characteristics were&#xd;
examined. A Set of experiments independent of the mass&#xd;
transfer work was carried out in order to study mixing in&#xd;
the column. A refluxing mechanism is uncovered in the mixing&#xd;
experiments. Values for the axial dispersion coefficient,&#xd;
volumetric mass transfer coefficient and reflux ratio are&#xd;
reported over the range of the operating parameters.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Engineering (MEngr)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">oxygen transfer</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">pulsed bubble</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">bubble column</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">chemicals</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Oxygen Transfer in a Countercurrent, Pulsed Bubble Column</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>