<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T02:44:34Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/20531" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/20531</identifier><datestamp>2026-09-24T06:43:55Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Luxat, John</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Yu, Changrui</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Engineering Physics</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2016-09-26T15:37:56Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2016-09-26T15:37:56Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2016</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/20531</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/15099</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">A thermal hydraulic analysis has been conducted to investigate the conditions leading&#xd;
to the channel flow reversal and the subsequent effects that may have on the Primary&#xd;
Heat Transfer System(PHTS) thermohydraulic parameters during the natural circulation&#xd;
under the specific accident scenarios for a generic CANDU 900 MW plant model&#xd;
similar to Darlington NGS. The assumed initiating events are the combination of a&#xd;
small Loss Of Coolant Accident (LOCA) with a loss of Class IV power, as well as the&#xd;
unavailability of Emergency Coolant Injection (ECI) system. No makeup inventory&#xd;
is taken into account in this study, and there is no fuel sheath temperature excursion&#xd;
or fuel centerline melting, i.e., the integrity of fuel is always maintained.&#xd;
A one-dimensional quasi-steady state Homogeneous Equilibrium Model(HEM) has&#xd;
been constructed for the study. A specific node-link structure is adopted to represent&#xd;
the primary heat transfer loop: The whole loop and different components in HTS are&#xd;
represented by a series of nodes that have quasi-static thermal hydraulic characteristics&#xd;
such as pressure and enthalpy, etc. Dynamic characteristics are delivered by the&#xd;
links between nodes, e.g., flow rate and pressure drop. The channel powers (decay&#xd;
heat), the secondary side pressure and the pressure at Reactor Inlet Header(RIH) are&#xd;
chosen as boundary conditions to describe the assumed initiating incidents for the&#xd;
iii&#xd;
model.&#xd;
With ongoing loss of inventory and system depressurization, vapor lock occurs&#xd;
in Steam Generator(SG), and it increases the pressure drop from Reactor Outlet&#xd;
Header(ROH) to RIH across SG and forms an increasingly negative RIH-to-ROH&#xd;
pressure differential. Flow reversal occurs in the channel due to the counter force balance&#xd;
between negative RIH-to-ROH pressure difference and the driving force derived&#xd;
from the density difference between the hot and cold legs. It is found that channels&#xd;
in row A have the highest reversal preference, then followed by the channels in row B,&#xd;
and in that order subsequently. Row A reverses when inventory decreases to about&#xd;
79.5% of initial value, with following boundary conditions: decay heat is 1.5% of Full&#xd;
Power(FP) and secondary side pressure is 5.070 MPa. In addition, it is found that the&#xd;
decrease in channel power accelerates the depressurization process and brings forward&#xd;
the occurrence of flow reversal in fuel channels.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Applied Science (MASc)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">flow reversal</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">natural circulation</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Analysis of Flow Reversal under Two-Phase Natural Circulation in CANDU9 during Small Loss of Coolant Accident with Loss of Class IV Power</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>