<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T04:13:43Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/20647" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/20647</identifier><datestamp>2026-09-24T19:38:48Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Luxat, John</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Dion, Alexander</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Engineering Physics</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2016-10-05T19:40:24Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2016-10-05T19:40:24Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2016</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/20647</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/13719</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Under normal operating conditions a CANDU reactor pressure tube (PT) is insulated from its outer calandria tube (CT) by a CO2 gas annulus. If the primary loop coolant flow is compromised the PT can overheat and, if still pressurized, balloon into contact with the CT. At this point the moderator acts as an emergency heat sink. If the heat transferred from the CT to the moderator exceeds the critical heat flux (CHF) the CT can overheat, begin to strain due to the contact pressure, and eventually fail. A mechanistic model is presented that describes ballooning contact of the PT and CT, the resulting thermal contact conductance, heat flux to the moderator, and, if CHF is exceeded, the development of film boiling and potential CT strain. The goal is to create a software package that predicts fuel channel failure during a pressure tube overheat event.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Applied Science (MASc)</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="layabstract" lang="en_US">Computer software was developed to predict CANDU fuel channel failure in the event of a total station blackout. The model created successfully predicted the available experimental data.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Thermal Hydraulics</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">CANDU</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Fuel Channel Failure</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Film Boiling</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">A Mechanistic Model to Predict Fuel Channel Failure in the Event of Pressure Tube Overheating</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">A Model to Predict Fuel Channel Failure</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>