<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T05:03:40Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/22234" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/22234</identifier><datestamp>2026-09-24T06:00:12Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Latulippe, David</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">El-Assaad, Wael</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Chemical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2017-10-17T12:50:34Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2017-10-17T12:50:34Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2017</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/22234</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/20991</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">The main purpose of specialized industrial wastewater treatment facilities is to&#xd;
treat incoming wastewater loads from various industries which do not have the&#xd;
capability of treating their wastewater on site. Accordingly, specialized industrial&#xd;
wastewater treatment facilities face a challenge in quickly identifying optimal treatment&#xd;
options for the varying incoming wastewater loads they receive. With the new discharge&#xd;
limits set by the federal Wastewater System Effluent Regulations (WSER) and a&#xd;
compliance deadline by 2020, it became crucial for such facilities to optimize their&#xd;
processes and ensure having a method to determine optimal treatment options and&#xd;
conditions to meet the new discharge limits. One such limit is the Chemical Oxygen&#xd;
Demand (COD), which is representative of the amount of organic matter present in a&#xd;
solution.&#xd;
Polymer flocculation is a common mechanism used for solid-­liquid separation in&#xd;
industrial wastewater treatment. While many previous research studies have been&#xd;
previously conducted on polymer flocculation and industrial wastewater treatment, there&#xd;
seems to be a lack in studies that focus on running experiments in a rapid high-­&#xd;
throughput manner and using samples that vary in composition and come from different&#xd;
generators/sources.&#xd;
In this work, a high-­throughput method was implemented to investigate several&#xd;
aspects in the polymer flocculation area on various wastewater samples obtained from&#xd;
a specialized industrial wastewater treatment facility. Using this method, the optimum&#xd;
polymer flocculant type, dosage and concentration were successfully identified for&#xd;
several wastewater samples. In addition to that, scale-­up experiments were done in the&#xd;
v&#xd;
facility on various wastewater tanks to compare the performance of undiluted and&#xd;
diluted polymer flocculant. Diluted polymer flocculant was proven to successfully treat&#xd;
wastewater tanks to a level safe enough for discharge and just as good as undiluted&#xd;
polymer flocculant while using less “neat” polymer flocculant volumes. Moreover,&#xd;
possible cost savings and a better treated water quality were also achieved by&#xd;
implementing multi-­staged polymer flocculation concept for industrial wastewater on a&#xd;
small scale.&#xd;
This work also focused on testing the FBRM as an in-­line method for particle size&#xd;
distribution measurements in industrial wastewater. However, even after an optimization&#xd;
attempt, it did not work well on the samples tested. Another in-­line method that was also&#xd;
tested was UV spectroscopy. This method was proven to successfully work as a&#xd;
method to determine optimum polymer flocculant dose and could be a promising in-­line&#xd;
tool.&#xd;
Finally, bentonite was used as a flocculation aid along with polymer flocculants&#xd;
and design of experiments (DOE) methods were implemented to almost successfully&#xd;
reduce the COD, which as mentioned is an important water quality parameter, in&#xd;
automotive industrial wastewater samples with initial average COD of 77,000 ppm to the&#xd;
safe discharge limit (i.e. 600 ppm)</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Applied Science (MASc)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">A Study on Polymer-induced Flocculation in Industrial Wastewater Treatment Via a High-throughput Method</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>