<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T03:32:35Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/22266" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/22266</identifier><datestamp>2026-09-24T06:34:43Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Kruse, Peter</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Sharif, Md Omar</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Chemistry and Chemical Biology</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2017-10-18T12:32:11Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2017-10-18T12:32:11Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2017</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/22266</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/11386</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Disinfectants are added to the water distribution system and swimming pools to&#xd;
control the growth of pathogenic microorganisms in water. High disinfectant levels are&#xd;
health hazards since they produce disinfectant by-products which are carcinogens. Thus,&#xd;
monitoring the amount ofresidual disinfectants present and maintaining an optimal amount&#xd;
of residual disinfectants throughout the distribution network is very crucial for safe water&#xd;
distribution. Colorimetric measurements are the current standard for measuring disinfectant&#xd;
levels in water. However, it is very difficult to integrate colorimetric measurements into&#xd;
automated monitoring devices. Redox active molecules like the phenyl-capped aniline&#xd;
tetramer (PCAT) can be incorporated as a dopant into a single wall carbon nanotube sensor&#xd;
for detecting oxidant in drinking water. The sensor works on the principle of oxidizing&#xd;
adsorbed redox molecules on carbon nanotubes by oxidant present in drinking water thus&#xd;
changing the resistivity of the carbon nanotube film. Most commonly used disinfectants are&#xd;
HOCl, Cl2, ClO2, Chloramine, KMnO4, HOBr, H2O2, O3, Br2, I2, etc. They all are oxidizing&#xd;
agents and can be distinguished from one another as they have different oxidation potentials.&#xd;
For water treatment purposes, it is not enough to know the disinfectant level, but it is also&#xd;
very important to identify which disinfectant is present. Currently, there is no standard&#xd;
method for distinguishing different disinfectants presents in water. The development of&#xd;
sensor arrays based on redox active molecules having different redox potentials is a&#xd;
potential pathway towards differentiating between different disinfectants in water.&#xd;
Different aniline oligomers were synthesized to create a library of redox active molecules.&#xd;
Redox properties of these molecules have been determined, and expected results were&#xd;
compared with the sensor performance. In the future, these sensors can be incorporated into&#xd;
a reliable, resettable and reagent free sensor array for monitoring and distinguishing&#xd;
different disinfectants in water. Being able to constantly monitor the disinfectant level and&#xd;
identifying the disinfectant present in water will enable us to design an improved and&#xd;
sustainable disinfecting system.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Science (MSc)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Disinfectant</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Water Quality</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Redox molecule</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Chemiresistor</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Free chlorine</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Disinfectant monitoring</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Carbon nanotube</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Towards Identifying Disinfectants and Quantifying Disinfectant Levels in Water</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>