<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T03:39:52Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/22816" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/22816</identifier><datestamp>2026-09-24T01:38:17Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Selvaganapathy, Ponnambalam Ravi</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Ghaemi, Reza</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2018-05-03T17:25:18Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2018-05-03T17:25:18Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2017</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/22816</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/19795</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Drosophila  melanogaster  has  long  been  a  preferred  model  organism  for  the  study  of &#xd;
developmental, genetic,  and  biochemical  processes. They  have only  four chromosomes &#xd;
and  a  comparably  simple  morphology.  Given  that  60%  of  Drosophila  proteins  share &#xd;
homologs with humans, this allows for the effective study of biological processes that are &#xd;
of importance in human and vertebrate models. The conventional drug discovery assays &#xd;
using Drosophila are manual and require skill operator, which makes them expensive and &#xd;
unsuitable  for  high-throughput  screening.  Hence,  technologies  to  address  the  existing &#xd;
challenges involved in the conventional Drosophila-based assays (either in embryonic or &#xd;
larva  stage)  would  greatly  facilitate  drug  discovery  process.  In  this  thesis, &#xd;
microfabrication  and  microfluidics  engineering  approaches  have  been  utilized  in &#xd;
Drosophila-based  assays  due  to their  potential  to obtain  high  accurate  positioning  and &#xd;
reagent  delivery  in  a  low-cost,  rapid  and  potentially  automated  manner.  At  embryonic &#xd;
stage, the first microinjector that allow one to precisely insert a long taper microneedle &#xd;
laterally  and  at  various  positions  inside  the  length  of  the  Drosophila  embryo  (up  to &#xd;
250µm)  was  developed.  Using  this  device,  it  was  demonstrated  that  the  cardioblast &#xd;
migration  velocity  is  modified  in  a  dose  sensitive  manner  to  varying  doses  of  injected &#xd;
Sodium  Azide  (NaN3).  At  larva  stage,  a  systematic  analysis  of  various  mechanical &#xd;
constrictions  incorporated into microfluidic channels were conducted. This could allow &#xd;
one to find an optimized design for rapid mechanical immobilization of larvae for whole-&#xd;
CNS imaging. The optimal immobilization mechanism has been used for immobilization &#xd;
and live-intact fluorescence functional imaging of Drosophila larva's CNS in response to &#xd;
controlled  acoustic  stimulation  using  a  Genetically  Encoded  Calcium  Indicator  (GECI) &#xd;
probe,  called  GCaMP5.  The  microfluidics  clamps  developed  could  immobilized &#xd;
Drosophila  larvae  for  only  whole-CNS  imaging  and  they  cannot  allow  one  to  capture &#xd;
neuronal responses at single-neuron resolution, which requires stronger immobilization. &#xd;
In  this  thesis,  a  simple  microfluidic  device,  which  employed  an  interesting  strategy  to &#xd;
completely  immobilize  the  brain  and  the  CNS  of  a  live,  fully-functioning  Drosophila &#xd;
larva was demonstrated. This enables one, for the first time, to imaging throughout these &#xd;
organs  at  a  single  neuron  resolution.  None  of  the  mechanical  immobilization  methods &#xd;
available currently are capable of immobilization of the brain and the CNS of a live fully &#xd;
functioning  Drosophila  larva  for  intact  imaging  at  a  single  neuron  resolution.  The &#xd;
application  of  this  platform  was  not  limited  to  brain  and  CNS  imaging  and  it  can &#xd;
potentially being used to record neuronal events at different organs such as gut, intestine &#xd;
and hearts in a fully intact manner.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Doctor of Philosophy (PhD)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Microfluidics devices for Drosophila-based drug discovery assays</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>