<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T03:39:51Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/23880" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/23880</identifier><datestamp>2026-09-24T05:03:39Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Deen, M. Jamal</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Zheng, Xiaoqing</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Electrical and Computer Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2019-02-07T14:27:46Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2019-02-07T14:27:46Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2017</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/23880</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/22258</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">The wide band gap semiconductor Cadmium Zinc Telluride (CZT) is of recent&#xd;
interest for medical imaging at room temperature. A number of properties, including&#xd;
superior energy resolution, 3D photon position sensitivity, compact size, direct&#xd;
photon conversion and energy-resolving capability, make CZT a promising candidate&#xd;
for positron emission tomography (PET) and photon-counting X-ray imaging systems.&#xd;
Despite these advantages, drawbacks, such as low mobility of holes, hole trapping,&#xd;
charge sharing effect and characteristic X-ray escape degrade the performance of&#xd;
large volume CZT detectors.&#xd;
In this research, characterization and evaluation of single-crystal CZT photon&#xd;
detector using simulation and experimental studies were done. First, a comprehensive&#xd;
analytical model was developed and implemented by using Monte Carlo simulation&#xd;
and finite element analyses. This model includes the generation and transportation of&#xd;
charge carries within CZT detectors, and it provides useful guidance in optimizing the&#xd;
electrode design and associated readout circuits.&#xd;
Second, the performance of a 20×20×5mm3&#xd;
 CZT crystal with 8×8 pixel anodes&#xd;
and a planar cathode was integrated with readout electronics that can be used to build&#xd;
a PET system was studied. The experiments demonstrate an energy resolution of&#xd;
~2.26±0.84% full width half maximum (FWHM) at 662 keV and 19±3 ns&#xd;
coincidence time resolution with planar parallel field configuration. A novel&#xd;
algorithm based on charge sharing effect and transient signal analysis targeting the&#xd;
improvement of spatial resolution, was proposed. The sub-pitch spatial resolution is&#xd;
found to be ~30 µm and ~250 µm under signal-to-noise ratio of ~17, for inside and&#xd;
outside the valid range of charge sharing, respectively.&#xd;
Finally, the feasibility of CZT in photon-counting Computed Tomography (CT)&#xd;
was studied by using monoenergetic sources, with a special attention paid to energy&#xd;
degradation due to characteristic X-ray escape and the charge sharing effect. The&#xd;
effects of detector configuration and incident beam location were also investigated.&#xd;
The results show that the pixel size can be reduced to 500 µm without significant&#xd;
count loss (~5%) and charge loss (~15%) for the photo-counting X-ray applications.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Doctor of Philosophy (PhD)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">CZT</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Medical Imaging</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">INVESTIGATION OF CADMIUM ZINC TELLURIDE DETECTOR FOR MEDICAL IMAGING APPLICATIONS</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>