<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T02:02:49Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/25591" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/25591</identifier><datestamp>2026-09-24T06:36:51Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Noseworthy, Michael, D.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Nguyen, Jimmy</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Electrical and Computer Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2020-08-12T18:35:59Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2020-08-12T18:35:59Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2020</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/25591</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/18858</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Traditional 1H lung imaging using MRI faces numerous challenges and difficulties due&#xd;
to low proton density and air-tissue susceptibility artifacts. New imaging techniques&#xd;
using inhaled xenon gas can overcome these challenges at the cost of lower signal to&#xd;
noise ratio. The signal to noise ratio determines reconstructed image quality and is&#xd;
an essential parameter in ensuring reliable results in MR imaging. The traditional RF&#xd;
surface coils used in MR imaging exhibit an inhomogeneous field, leading to reduced&#xd;
image quality. For the last few decades, fractal-shaped antennas have been used to&#xd;
optimize the performance of antennas for radiofrequency systems. Although widely&#xd;
used in radiofrequency identification systems, mobile phones, and other applications,&#xd;
fractal designs have yet to be fully researched in the MRI application space. The use of&#xd;
fractal geometries for RF coils may prove to be fruitful and thus prompts an investiga-&#xd;
tion as the main goal of this thesis. Preliminary simulation results and experimental&#xd;
validation results show that RF coils created using the Gosper and pentaflake offer&#xd;
improved signal to noise ratio and exhibit a more homogeneous field than that of a&#xd;
traditional circular surface coil.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Applied Science (MASc)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">xenon imaging magnetic resonance fractal mri coil rf radiofrequency design simulation verification</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Fractal-based magnetic resonance imaging coils for 3T Xenon imaging</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>