<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T06:32:06Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/27539" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/27539</identifier><datestamp>2026-09-24T06:27:47Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Buijs, Adriaan</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Alkan, Cahit</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Engineering Physics and Nuclear Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2022-05-10T15:33:17Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2022-05-10T15:33:17Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2022</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/27539</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/10604</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Around the world, countries are increasingly considering carbon-free energy generation&#xd;
options as the threat of climate change grows. Small modular reactor designs,&#xd;
promising such carbon-free energy generation, are thriving worldwide with novel and&#xd;
innovative technologies that improve safety as well as economic performance. Canada&#xd;
is also considering small modular reactors (SMRs) as a means of achieving net zero&#xd;
carbon emissions by 2050.&#xd;
Some of these reactor designs utilize pressurized water for cooling and moderator.&#xd;
Reactors with pressurized water have been subjected to steam generator tube ruptures&#xd;
in the past, and a detailed investigation into the possible consequences of such incidents&#xd;
in SMRs should be conducted.&#xd;
In this research, a model for one of the newer designs, the NuScale Integrated Small&#xd;
Modular Reactor, was developed with the RELAP5-3D code for assessing safety related&#xd;
transients. The NuScale Small Modular Reactor incorporates helical coil steam&#xd;
generators within its reactor pressure vessel, which are more efficient in terms of heat&#xd;
transfer than the U-tube steam generators that are widely used in nuclear reactors.&#xd;
In the first part of the research, a detailed model is created and used to obtain steady&#xd;
state conditions with parameters collected from NuScale’s Final Safety Analysis Report&#xd;
(FSAR). The Steam Generator Tube Rupture event is analyzed in the second part&#xd;
of the work. Slight differences in the broken and intact steam generator pressures as&#xd;
well as decay heat removal system flow rates are seen in the comparison of reference&#xd;
values and calculated results. Among the reasons for those differences could be that&#xd;
the correlations used by the RELAP5-3D code for heat transfer coefficient and pressure&#xd;
drop in the helical coil steam generators are different than those of the NuScale proprietary&#xd;
code NRELAP5, with which the analyses have been performed in the FSAR.&#xd;
Also, post-dryout heat transfer at the exit of helical coil steam generators and evaporator&#xd;
sections could cause differences in the outlet conditions of the steam, resulting in&#xd;
different mass flow rates as well.&#xd;
The final section of the research simulates a comparable but more severe tube rupture&#xd;
incident without the availability of decay heat removal systems in order to assess&#xd;
the reactor’s emergency core cooling system reaction. Passive decay heat removal systems&#xd;
are crucial components for removing heat after reactor shutdown through heat&#xd;
exchangers that are submerged in the reactor pool and connected to steam generators&#xd;
by a closed loop. The containment pressures, the containment wall temperatures, and&#xd;
the peak fuel clad temperatures are considered to be the key design constraints that&#xd;
must be observed.&#xd;
Future work on this subject could include modifying the source code, adding specific&#xd;
correlations for helical coil steam generators, and comparing the results, as well&#xd;
as quantifying uncertainties in the SGTR event. Main parameters in the quantification&#xd;
of uncertainties would be reactor power, single phase and two-phase discharge coefficients&#xd;
from the break, trip signals and delays as well as break size and location.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Applied Science (MASc)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">small modular reactors</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">safety analysis</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">nuscale</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">helical coil steam generators</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">relap5</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Evaluation of Safety Transients in Helical Coil Steam Generators with RELAP5-3D Code</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">Safety Transients in Helical Coil Steam Generators</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>