<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T02:18:09Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/27632" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/27632</identifier><datestamp>2026-09-24T22:04:33Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Soleymani, Leyla</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Toteng, Larona</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Biomedical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2022-06-14T17:29:13Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2022-06-14T17:29:13Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2019</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/27632</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/16460</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">To reduce the incidence of clinical complications and cost associated with Urinary Tract&#xd;
infections (UTIs), there is a need for the development of a low-cost and culture-free UTI&#xd;
diagnostic test with a rapid sample-to-answer time. The aim of this study is to develop an&#xd;
electrochemical assay for nucleic acid detection that is sensitive and specific. We sought&#xd;
to develop such system by creating an assay that combines low background signals with&#xd;
built-in amplification.&#xd;
In this work, gold disk macroelectrodes are used in conjunction with a bio-recognition&#xd;
layer to capture pathogen-related nucleic acids and then this event is translated into an&#xd;
electrochemical signal. At first DNA was used as the bio-recognition layer. However, to&#xd;
enhance the system’s limit-of-detection (LOD), we developed an assay based on the&#xd;
neutral bio-recognition layer, peptide nucleic acid (PNA). PNA produced a lower&#xd;
background signal compared to DNA and a LOD of 0.001 nanomolar. In order to take&#xd;
advantage of isothermal and low-temperature nucleic acid amplification towards further&#xd;
enhancing the system’s LOD, a new assay based on programmable strand displacement&#xd;
coupled with electrochemical readout was employed. The system employed target cycling&#xd;
to produce in-built amplification. With this assay a LOD of 0.5 nM was achieved. Further&#xd;
tuning of probe densities is required to realise lower LODs.&#xd;
These results illustrate how using PNA produces a lower background signal compared to&#xd;
DNA and that employing a programmable strand displacement assay introduces built&#xd;
amplification into a system. Future studies combining the two systems would be ideally&#xd;
suited for realising an assay that is sensitive and specific.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Applied Science (MASc)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">A Study of the Development of an Electrochemical Point-of-Care Urine Analysis Platform for Pathogen Screening</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>