<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T02:02:58Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/30294" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/30294</identifier><datestamp>2026-09-24T18:56:39Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Shirani, Shahram</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Hassani Najafabadi, Seyed Mohammad Mehdi</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Electrical and Computer Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2024-10-02T14:19:45Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2024-10-02T14:19:45Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2024</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/30294</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/8696</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">The enduring challenge in computed tomography (CT) imaging is mitigating the&#xd;
radiation risks associated with high-dose protocols while maintaining image quality.&#xd;
This research introduces an innovative approach that diverges significantly&#xd;
from conventional methodologies, using Generative Diffusion Models (GDM) to&#xd;
enhance the quality of low-dose CT scans to that of high-dose scans. This advancement&#xd;
is particularly pivotal as it addresses the crucial balance between minimizing&#xd;
radiation risk and preserving diagnostic integrity. At the heart of our approach&#xd;
is a distinctive application of a Convolutional Neural Network (CNN) designed&#xd;
not to filter noise but to meticulously identify and segregate intrinsic noise features&#xd;
within paired high and low-dose CT images. This method stands in contrast&#xd;
to traditional techniques that often rely on generic random noise models, lacking&#xd;
specificity to actual imaging conditions. By accurately modeling the unique noise&#xd;
profile of low-dose scans, we enable our GDM to undertake a reverse diffusion&#xd;
process, effectively reducing noise and enhancing image clarity to equal high-dose&#xd;
standards. The significance of transitioning from low-dose to high-dose imaging&#xd;
quality without additional radiation is offering a path to safer imaging protocols&#xd;
that do not compromise quality. We present preliminary findings substantiated&#xd;
by both PSNR and SSIM metrics, demonstrating improvement in image quality&#xd;
through our method. In addition to delineating our approach, this research draws&#xd;
comparisons with existing methods, particularly focusing on PALLETE, a known&#xd;
algorithm in the field. Our comparative analysis illustrates the superiority of our&#xd;
model in terms of image quality, showcasing our method’s potential for enhancement&#xd;
in radiological imaging.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Computer Engineering (MCompE)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Enhancing Quality of Low-Dose CT Scans Via Generative Diffusion Models</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>