<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T03:40:07Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/33126" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/33126</identifier><datestamp>2026-09-24T22:56:52Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Madden, Kim</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Basra, Gurjot</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Health Sciences</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2026-05-11T15:12:10Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2026</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="issn">Markerless Motion Capture Gait Testing, Orthopaedic Surgery, Patient Reports, Feasibility in Clinic</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/11375/33126</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/22630</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Background: Markerless motion capture systems provide a non-invasive method to assess gait in orthopedic patients. Understanding patient perspectives on feasibility and preferences for data reporting is critical for integrating this technology into routine clinical care.

Methods: This cross-sectional study surveyed 383 patients at a Hamilton based orthopedic center, including 219 knee, 27 hip, and 126 shoulder patients. The survey assessed willingness to participate in in-clinic gait assessments across multiple time points, perceived feasibility, and preferences for patient-facing gait reports. Open-ended responses were analyzed thematically to identify barriers and facilitators to participation.

Results: Most patients (81.2%) perceived gait assessments as feasible, with minimal privacy or safety concerns (85.4%). Willingness to participate was influenced by practical factors such as travel distance, time constraints, and alignment with routine appointments. Reduced interest was observed at 3 and 6-month postoperative assessments requiring additional clinic visits. Secondary considerations included cost, perceived value, and understanding of the technology, with a participant expressing concerns about “scanning” or potential “radiation,” despite marker-less systems being non-ionizing.

Regarding report preferences, patients favored multimodal presentations combining descriptive language (69.4%), numerical data (61.1%), color-coded scales (55.3%), and visual representations of movement (67.1%), while only 32.1% preferred graphical data presentation. Longitudinal tracking of personal progress was valued by 73.6% of participants, whereas comparison to population norms was less meaningful (36.3-54%).

Conclusion: These findings indicate that markerless gait testing is both feasible and acceptable in outpatient orthopedic settings. Patient-centered reporting that is clear, interpretable, and visually intuitive may enhance understanding engagement in rehabilitation, and shared decision-making. Successful implementation is likely dependent on minimizing practical burdens by aligning assessments with existing appointments. These insights will inform the development of reports that effectively support decision-making for joint arthroplasty procedures and help facilitate the integration of gait testing into routine clinical practice.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype">Thesis</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Master of Public Health (MPH)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en">Attribution 2.5 Canada</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">http://creativecommons.org/licenses/by/2.5/ca/</dim:field>
   <dim:field mdschema="dc" element="subject">Markerless Motion Capture Gait Testing</dim:field>
   <dim:field mdschema="dc" element="subject">Orthopaedic Surgery</dim:field>
   <dim:field mdschema="dc" element="subject">Patient Reports</dim:field>
   <dim:field mdschema="dc" element="subject">Feasibility in Clinic</dim:field>
   <dim:field mdschema="dc" element="title">PATIENT PERSPECTIVES REGARDING FEASIBILITY OF MARKERLESS MOTION CAPTURE-BASED GAIT TESTING IN AN ORTHOPAEDIC CLINIC, AND PRESENTING COMPREHENSIBLE GAIT LAB REPORTS</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative">PERCIEVED FEASIBILITY OF MARKERLESS MOTION CAPTURE-BASED GAIT TESTING AND PRESENTING GAIT LAB REPORTS</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Thesis</dim:field>
   <dim:field mdschema="others" element="access-status">embargo</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>