<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T01:45:55Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/33141" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/33141</identifier><datestamp>2026-05-14T16:17:46Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Deen, M Jamal</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Faisal, Abu Ilius</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Electrical and Computer Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2026-05-13T14:47:43Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2026</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/11375/33141</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/5</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Continuous and objective assessment of human mobility and physiological health is essential for the early detection, monitoring, and management of age-related functional decline and chronic conditions. However, conventional clinical assessment tools are often constrained by high cost, short observation windows, and limited ecological validity. To address these limitations, robust, low-cost, and interpretable wearable sensing frameworks for holistic mobility and health assessment in real-world environments are developed and presented in this thesis.
A magnetometer-free inertial measurement unit (IMU)-based framework is established to jointly estimate lower-limb kinematics, reconstruct drift-corrected spatial trajectories, and extract comprehensive gait parameters during ambulatory walking. The framework integrates adaptive filtering and stride-level drift compensation and is validated against optical reference systems, demonstrating reliable estimation of joint kinematics and spatial gait measures under real-world conditions. Building on this framework, wearable-derived gait and joint features are characterized using machine-learning methods to identify mobility patterns associated with age, body mass index, and sex. To enhance clinical interpretability, a simple Human Gait Index is formulated by integrating key spatiotemporal and kinematic parameters into a compact and interpretable measure of overall gait quality.
In parallel, a low-cost, chest-mounted multimodal wearable system is developed and validated for continuous physiological monitoring. The system integrates synchronized electrocardiography, photoplethysmography, inertial, temperature, and acoustic sensing to estimate cardiovascular, respiratory, and infection-related parameters during daily activities. Finally, real-world remote monitoring is applied in a cohort of older adults with and without chronic low back pain, demonstrating the feasibility of long-term wearable assessment and showing that machine-learning models applied to activity-derived features can distinguish pain-related mobility patterns that are not observable through conventional clinic-based evaluations.
Overall, the work presented in this thesis advances wearable sensing methodologies that bridge biomechanics, physiology, and data-driven analytics, enabling scalable, interpretable, and ecologically valid monitoring to support tele-health applications and personalized care.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype">Thesis</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Doctor of Philosophy (PhD)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher">McMaster University</dim:field>
   <dim:field mdschema="dc" element="subject">Wearable systems</dim:field>
   <dim:field mdschema="dc" element="subject">Multimodal sensing</dim:field>
   <dim:field mdschema="dc" element="subject">Gait analysis</dim:field>
   <dim:field mdschema="dc" element="subject">Inertial measurement units (IMU)</dim:field>
   <dim:field mdschema="dc" element="subject">Physiological monitoring</dim:field>
   <dim:field mdschema="dc" element="subject">Human gait index</dim:field>
   <dim:field mdschema="dc" element="subject">Remote health monitoring</dim:field>
   <dim:field mdschema="dc" element="subject">Machine learning</dim:field>
   <dim:field mdschema="dc" element="subject">Biomechanics</dim:field>
   <dim:field mdschema="dc" element="subject">Continuous health monitoring</dim:field>
   <dim:field mdschema="dc" element="title">Multimodal Wearable Systems Towards Continuous Monitoring of Mobility and Physiological Health</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative">Wearable Systems for Mobility and Health Monitoring</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="others" element="access-status">embargo</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>