<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T01:15:32Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/33593" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/33593</identifier><datestamp>2026-09-24T21:51:00Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Selvaganapathy, Ponnambalam</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Sojan, Anand</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2026-09-23T18:31:47Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2026</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/11375/33593</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/25364</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Respiratory Distress Syndrome (RDS) is prevalent in preterm neonatal population, mainly arising from the immaturity of the lungs. Extracorporeal membrane oxygenation (ECMO) is used as an alternative to mechanical ventilation, where blood oxygenation is performed using hollow fiber oxygenator modules. But as these devices are not suitable for preterm population, microfluidic-based blood oxygenators are explored, due to their small priming volume and operational potential for artificial placental integration. However, clinical transition is limited by the challenge to scalability and manufacturability, arising from their reliance on conventional microfabrication techniques for fabrication. Recently, additive manufacturing (AM) techniques are being explored as alternatives but are still limited in their ability to manufacture scalable and completely patent microfluidic devices.
The goal of this doctoral thesis is to advance the manufacturability of microfluidic-based oxygenators with objectives, both to overcome the limitations of conventional microfabrication and to demonstrate alternative fabrication methods to push microfluidic oxygenators towards clinical translation. We explored both sacrificial extrusion printing and rapid membrane printing for realization of these goals. In case of the sacrificial printing, molten isomalt formed the etch-away microchannels, providing a biosafe alternative to synthetic polymers and etching solvents. While the gas exchange membranes were predominantly polydimethylsiloxane (PDMS), in the later part of the research, an ultrafiltration polyethersulfone (PES) membrane was added to demonstrate integrated oxygenation-ultrafiltration modules, capable of fluid and solute clearance. In addition, a rapid cure embedded printing technique was demonstrated, by which 3d gas exchange membrane constructs can be fabricated for future device development. From an application standpoint, lung assist devices were prototyped using one of the established techniques. The devices were successfully able to operate within the priming volume and perfusion requirements, while surpassing the oxygen uptake required to support a 1 kg preterm infant suffering from RDS. Future work on scaling the devices and modification of blood contact surfaces are recommended at the end of the thesis so that prototypes demonstrated in this thesis contribute to the development of artificial placenta technology for pre-term infants.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="sponsorship">CIHR, NSERC</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degreetype">Dissertation</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Doctor of Philosophy (PhD)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en_US</dim:field>
   <dim:field mdschema="dc" element="subject">Microfluidic oxygenators</dim:field>
   <dim:field mdschema="dc" element="subject">Artificial Placenta</dim:field>
   <dim:field mdschema="dc" element="subject">Lung Assist Device</dim:field>
   <dim:field mdschema="dc" element="subject">Additive Manufacturing</dim:field>
   <dim:field mdschema="dc" element="title">Additive Manufacturing Strategies for Engineering the Next Generation of Microfluidic-based Lung Assist Devices</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="others" element="access-status">embargo</dim:field>