<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T01:51:55Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/8689" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/8689</identifier><datestamp>2026-09-24T20:43:55Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Tait, Michael J.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Cassolato, Richard Marcus</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Civil Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2014-06-18T16:43:41Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2014-06-18T16:43:41Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="created" lang="en_US">2011-01-26</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2007-05</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="other" lang="en_US">opendissertations/3873</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="other" lang="en_US">4890</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="other" lang="en_US">1746763</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/8689</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/15491</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">&lt;p>ABSTRACT&lt;/p> &lt;p>The first application of the tuned liquid damper (TLD) to mitigate the&lt;/p> &lt;p>dynamic vibrations of structures was only around 20 years ago and has just been&lt;/p> &lt;p>recently applied in North America. TLDs are partially fluid filled tanks (usually&lt;/p> &lt;p>water) with a fundamental sloshing frequency tuned close to the frequency of the&lt;/p> &lt;p>dynamic mode of structural vibration to be suppressed. Water alone is&lt;/p> &lt;p>insufficient to achieve the level of damping typically required for design.&lt;/p> &lt;p>Damping devices are often submerged in the water to greatly increase the inherent&lt;/p> &lt;p>TLD damping. The damping device investigated in this study is a thin sharpedged&lt;/p> &lt;p>horizontal-slat screen. TLDs with such screens of a particular solidity are&lt;/p> &lt;p>designed for one target amplitude of structural response and have limited&lt;/p> &lt;p>efficiency over a range of structural response. To increase the efficiency, the&lt;/p> &lt;p>concept of smart screens is introduced in this study.&lt;/p> &lt;p>Smart screens is the name given to a damping screen that alters its fluid&lt;/p> &lt;p>pressure-loss characteristics at differing levels of excitation, (ideally) in a passive&lt;/p> &lt;p>state of control. Symmetric fixed-angle screens and oscillating (rotating) parallellinked&lt;/p> &lt;p>screens are experimentally investigated inside a rectangular TLD on a&lt;/p> &lt;p>shake-table under sinusoidal motion in this study.&lt;/p> &lt;p>TLDs have similar principles to common tuned mass dampers (TMD) and&lt;/p> &lt;p>are analyzed accordingly. The TLD equipped with fixed-angle screens is&lt;/p> &lt;p>modelled with linear numerical fluid models to simulate the TLD performance for preliminary design purposes. An inclined screen alters the pressure-loss&lt;/p> &lt;p>characteristics from its typical vertical position, which in turn changes the&lt;/p> &lt;p>inherent TLD damping, allowing damping to be controlled by simple screen&lt;/p> &lt;p>rotation. The analytical models, including the utilization of a pressure-loss&lt;/p> &lt;p>coefficient for an inclined horizontal-slat screen in oscillatory flow developed in&lt;/p> &lt;p>this study, are compared with experimental results to verify their accuracy and&lt;/p> &lt;p>ascertain limitations.&lt;/p> &lt;p>Oscillating smart screens are investigated mainly for their practical&lt;/p> &lt;p>consideration in a preferred passive mode of control. The screens rotate&lt;/p> &lt;p>automatically with changes in fluid velocity (or excitation amplitude). Their&lt;/p> &lt;p>ability to maintain a near-constant amount of TLD damping (or resonant energy&lt;/p> &lt;p>dissipation) is examined. Other implementations of (passive) smart screens are&lt;/p> &lt;p>possible and suggestions for future study are recommended.&lt;/p> &lt;p>A TLD equipped with the mathematically modelled symmetric fixed-angle&lt;/p> &lt;p>screens is theoretically investigated in a hypothetical structure-TLD system. This&lt;/p> &lt;p>system demonstrates the ability of a smart screen to change its damping&lt;/p> &lt;p>characteristics-altering the angle of inclination in this study-over a range of&lt;/p> &lt;p>structural response thereby maintaining an optimal level of efficiency over a&lt;/p> &lt;p>range of structural response accelerations.&lt;/p></dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Applied Science (MASc)</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Civil Engineering</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Civil Engineering</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">The performance of a tuned liquid damper equipped with inclined and oscillating damping screens</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">thesis</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>