<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-21T01:23:43Z</responseDate><request verb="GetRecord" identifier="oai:macsphere.mcmaster.ca:11375/8958" metadataPrefix="dim">https://prod-ms-be.lib.mcmaster.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:macsphere.mcmaster.ca:11375/8958</identifier><datestamp>2026-09-24T18:52:12Z</datestamp><setSpec>com_11375_271</setSpec><setSpec>col_11375_272</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Filipe, Carlos</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Pelton, Robert</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Dr. Todd Hoare and Dr. Emily Cranston</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Leung, Vincent</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Chemical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2014-06-18T16:44:50Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2014-06-18T16:44:50Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="created" lang="en_US">2011-05-16</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2011-10</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="other" lang="en_US">opendissertations/4123</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="other" lang="en_US">5123</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="other" lang="en_US">2014937</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/11375/8958</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://doi.org/10.71548/13442</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">&lt;p>Research in paper-based analytical devices has been increasing rapidly in recent years. Manyof these devices are used as low-cost alternatives for diagnostics and biosensing. In this work,two novel paper-based technologies were developed.&lt;/p> &lt;p>The first paper-based technology achieved was measuring streaming potential on paper-based microfluidic devices. The streaming potential measurements were able to detect the presence of adsorbed polyvinylamine or potassium polyvinylsulfate in paper-based microfluidic channels.&lt;/p> &lt;p>The measured streaming potential ranged from -80 mV to 80 mV and the polarity was sensitive to the adsorbed polymer. Furthermore, the measured streaming potential on paper treated with BSA showed a polarity switch when the pH was changed from below the pKa to above the pKa of BSA. Lastly, streaming potential measurements may provide an electronic interface for paperbased sensors.&lt;/p> &lt;p>The second technology developed was a paper-based chromatographic pre-concentration device for biological and chemical applications. The device successfully concentrated a protein, streptavidin, via biotinylated microgels immobilized onto a selected area of the filter paper. The device was able to process a large volume of fluid with the incorporation of a passive pump made of superabsorbent polymer. The concentration factor achieved by the device was over 3000-fold. The flow dynamics through the paper was modeled using Darcy’s law. This technology could be an excellent low-cost alternative for biochemical analysis for samples thatrequire preconcentration, especially for the analysis of trace compounds in wastewater and drinking water.&lt;/p></dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Applied Science (MASc)</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Paper-based devices</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">microfluidics</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">biosensors</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">diagnostics</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Other Chemical Engineering</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Other Chemical Engineering</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Development of Paper-based Devices for Diagnostics and Biosensing</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">thesis</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>